Pump Specification Data | Standard | Option |
---|---|---|
Mains voltage | 400 V 3~ | 230, 500, 695 V* |
Voltage tolerance | ± 10% | - |
Motor efficiency | Premium Eff. IE3 | - |
Insulation class | H | - |
Start-up | Direct on line (DOL), star-delta (YΔ) | - |
Approvals | Ex / ATEX | - |
Mechanical seal (at medium side) | SiC-SiC-NBR | SiC-SiC-Viton |
Mechanical seal (at motor side) | SiC-C-NBR (80C - 150E), SiC-SiC-NBR (100G - 201G) | - |
O-rings (external seals) | NBR | Viton (not available for cable entry seal) |
Cables | H07RN8-F | EMC |
Cable length (m) | 10 | 20, 30, 40, 50 |
Protective coating | 2k Epoxy 120 μm | 2k Epoxy 400 μm |
Preparation for lifting hoist | Lifting hoop | - |
Cooling | Self-cooling (80C - 150E); by the medium (100G - 201G) | Closed cooling (100G - 201G) |
Installation | Wet-well | Dry well or transportable |
DIN Flange Connection | DN80 | - |
Clamp Connection | DN80 | - |
Weight | 110KG | - |
Speed | 1450RPM | - |
Motor Power (kW - 29/4) | 3.4kW (P1) | 3.0kW (P2) |